Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
J Med Virol ; 95(2): e28442, 2023 02.
Article in English | MEDLINE | ID: covidwho-2248007

ABSTRACT

Wastewater-based SARS-CoV-2 surveillance enables unbiased and comprehensive monitoring of defined sewersheds. We performed real-time monitoring of hospital wastewater that differentiated Delta and Omicron variants within total SARS-CoV-2-RNA, enabling correlation to COVID-19 cases from three tertiary-care facilities with >2100 inpatient beds in Calgary, Canada. RNA was extracted from hospital wastewater between August/2021 and January/2022, and SARS-CoV-2 quantified using RT-qPCR. Assays targeting R203M and R203K/G204R established the proportional abundance of Delta and Omicron, respectively. Total and variant-specific SARS-CoV-2 in wastewater was compared to data for variant specific COVID-19 hospitalizations, hospital-acquired infections, and outbreaks. Ninety-six percent (188/196) of wastewater samples were SARS-CoV-2 positive. Total SARS-CoV-2 RNA levels in wastewater increased in tandem with total prevalent cases (Delta plus Omicron). Variant-specific assessments showed this increase to be mainly driven by Omicron. Hospital-acquired cases of COVID-19 were associated with large spikes in wastewater SARS-CoV-2 and levels were significantly increased during outbreaks relative to nonoutbreak periods for total SARS-CoV2, Delta and Omicron. SARS-CoV-2 in hospital wastewater was significantly higher during the Omicron-wave irrespective of outbreaks. Wastewater-based monitoring of SARS-CoV-2 and its variants represents a novel tool for passive COVID-19 infection surveillance, case identification, containment, and potentially to mitigate viral spread in hospitals.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , RNA, Viral , Wastewater , Tertiary Care Centers , Disease Outbreaks
2.
J Environ Sci (China) ; 130: 139-148, 2023 Aug.
Article in English | MEDLINE | ID: covidwho-2180487

ABSTRACT

Wastewater surveillance (WS) of SARS-CoV-2 currently requires multiple steps and suffers low recoveries and poor sensitivity. Here, we report an improved analytical method with high sensitivity and recovery to quantify SARS-CoV-2 RNA in wastewater. To improve the recovery, we concentrated SARS-CoV-2 viral particles and RNA from both the solid and aqueous phases of wastewater using an electronegative membrane (EM). The captured viral particles and RNA on the EM were incubated in our newly developed viral inactivation and RNA preservation (VIP) buffer. Subsequently, the RNA was concentrated on magnetic beads and inhibitors removed by washing. Without eluting, the RNA on the magnetic beads was directly detected using reverse transcription quantitative polymerase chain reaction (RT-qPCR). Analysis of SARS-CoV-2 pseudovirus (SARS-CoV-2 RNA in a noninfectious viral coat) spiked to wastewater samples showed an improved recovery of 80%. Analysis of 120 wastewater samples collected twice weekly between May 2021 and February 2022 from two wastewater treatment plants showed 100% positive detection, which agreed with the results independently obtained by a provincial public health laboratory. The concentrations of SARS-CoV-2 RNA in these wastewater samples ranged from 2.4×102 to 2.9×106 copies per 100 mL of wastewater. Our method's capability of detecting trace and diverse concentrations of SARS-CoV-2 in complex wastewater samples is attributed to the enhanced recovery of SARS-CoV-2 RNA and efficient removal of PCR inhibitors. The improved method for the recovery and detection of viral RNA in wastewater is important for wastewater surveillance, complementing clinical diagnostic tests for public health protection.


Subject(s)
COVID-19 , RNA, Viral , Humans , Wastewater , SARS-CoV-2/genetics , Wastewater-Based Epidemiological Monitoring
3.
ACS ES T Water ; 2(11): 2243-2254, 2022 Nov 11.
Article in English | MEDLINE | ID: covidwho-2115772

ABSTRACT

The correlations between SARS-CoV-2 RNA levels in wastewater from 12 wastewater treatment plants and new COVID-19 cases in the corresponding sewersheds of 10 communities were studied over 17 months. The analysis from the longest continuous surveillance reported to date revealed that SARS-CoV-2 RNA levels correlated well with temporal changes of COVID-19 cases in each community. The strongest correlation was found during the third wave (r = 0.97) based on the population-weighted SARS-CoV-2 RNA levels in wastewater. Different correlations were observed (r from 0.51 to 0.86) in various sizes of communities. The population in the sewershed had no observed effects on the strength of the correlation. Fluctuation of SARS-CoV-2 RNA levels in wastewater mirrored increases and decreases of COVID-19 cases in the corresponding community. Since the viral shedding to sewers from all infected individuals is included, wastewater-based surveillance provides an unbiased and no-discriminate estimation of the prevalence of COVID-19 compared with clinical testing that was subject to testing-seeking behaviors and policy changes. Wastewater-based surveillance on SARS-CoV-2 represents a temporal trend of COVID-19 disease burden and is an effective and supplementary monitoring when the number of COVID-19 cases reaches detectable thresholds of SARS-CoV-2 RNA in wastewater of treatment facilities serving various sizes of populations.

4.
Journal of environmental sciences (China) ; 2022.
Article in English | EuropePMC | ID: covidwho-2058070

ABSTRACT

Image, graphical

5.
ACS ES&T water ; 2022.
Article in English | EuropePMC | ID: covidwho-2046390

ABSTRACT

The correlations between SARS-CoV-2 RNA levels in wastewater from 12 wastewater treatment plants and new COVID-19 cases in the corresponding sewersheds of 10 communities were studied over 17 months. The analysis from the longest continuous surveillance reported to date revealed that SARS-CoV-2 RNA levels correlated well with temporal changes of COVID-19 cases in each community. The strongest correlation was found during the third wave (r = 0.97) based on the population-weighted SARS-CoV-2 RNA levels in wastewater. Different correlations were observed (r from 0.51 to 0.86) in various sizes of communities. The population in the sewershed had no observed effects on the strength of the correlation. Fluctuation of SARS-CoV-2 RNA levels in wastewater mirrored increases and decreases of COVID-19 cases in the corresponding community. Since the viral shedding to sewers from all infected individuals is included, wastewater-based surveillance provides an unbiased and no-discriminate estimation of the prevalence of COVID-19 compared with clinical testing that was subject to testing–seeking behaviors and policy changes. Wastewater-based surveillance on SARS-CoV-2 represents a temporal trend of COVID-19 disease burden and is an effective and supplementary monitoring when the number of COVID-19 cases reaches detectable thresholds of SARS-CoV-2 RNA in wastewater of treatment facilities serving various sizes of populations. Fluctuation of SARS-CoV-2 RNA levels in wastewater reflects temporal trends of new COVID-19 cases in the community correspondingly.

6.
Sci Total Environ ; 856(Pt 1): 158964, 2023 Jan 15.
Article in English | MEDLINE | ID: covidwho-2042124

ABSTRACT

Wastewater-based surveillance (WBS) data normalization is an analyte measurement correction that addresses variations resulting from dilution of fecal discharge by non-sanitary sewage, stormwater or groundwater infiltration. No consensus exists on what WBS normalization parameters result in the strongest correlations and lead time between SARS-CoV-2 WBS data and COVID-19 cases. This study compared flow, population size and biomarker normalization impacts on the correlations and lead times for ten communities in twelve sewersheds in Alberta (Canada) between September 2020 and October 2021 (n = 1024) to determine if normalization by Pepper Mild Mottle Virus (PMMoV) provides any advantages compared to other normalization parameters (e.g., flow, reported and dynamic population sizes, BOD, TSS, NH3, TP). PMMoV concentrations (GC/mL) corresponded with plant influent flows and were highest in the urban centres. SARS-CoV-2 target genes E, N1 and N2 were all negatively associated with wastewater influent pH, while PMMoV was positively associated with temperature. Pooled data analysis showed that normalization increased ρ-values by almost 0.1 and was highest for ammonia, TKN and TP followed by PMMoV. Normalization by other parameters weakened associations. None of the differences were statistically significant. Site-specific correlations showed that normalization of SARS-CoV-2 data by PMMoV only improved correlations significantly in two of the twelve systems; neither were large sewersheds or combined sewer systems. In five systems, normalization by traditional wastewater strength parameters and dynamic population estimates improved correlations. Lead time ranged between 1 and 4 days in both pooled and site-specific comparisons. We recommend that WBS researchers and health departments: a) Investigate WWTP influent properties (e.g., pH) in the WBS planning phase and use at least two parallel approaches for normalization only if shown to provide value; b) Explore normalization by wastewater strength parameters and dynamic population size estimates further; and c) Evaluate purchasing an influent flow meter in small communities to support long-term WBS efforts and WWTP management.


Subject(s)
COVID-19 , Wastewater , Humans , SARS-CoV-2 , Alberta , Lead , Wastewater-Based Epidemiological Monitoring
7.
Emerg Infect Dis ; 28(9): 1770-1776, 2022 09.
Article in English | MEDLINE | ID: covidwho-1963355

ABSTRACT

Wastewater monitoring of SARS-CoV-2 enables early detection and monitoring of the COVID-19 disease burden in communities and can track specific variants of concern. We determined proportions of the Omicron and Delta variants across 30 municipalities covering >75% of the province of Alberta (population 4.5 million), Canada, during November 2021-January 2022. Larger cities Calgary and Edmonton exhibited more rapid emergence of Omicron than did smaller and more remote municipalities. Notable exceptions were Banff, a small international resort town, and Fort McMurray, a medium-sized northern community that has many workers who fly in and out regularly. The integrated wastewater signal revealed that the Omicron variant represented close to 100% of SARS-CoV-2 burden by late December, before the peak in newly diagnosed clinical cases throughout Alberta in mid-January. These findings demonstrate that wastewater monitoring offers early and reliable population-level results for establishing the extent and spread of SARS-CoV-2 variants.


Subject(s)
COVID-19 , SARS-CoV-2 , Alberta/epidemiology , COVID-19/epidemiology , Humans , SARS-CoV-2/genetics , Wastewater
8.
BMJ Open ; 11(8), 2021.
Article in English | ProQuest Central | ID: covidwho-1842919

ABSTRACT

IntroductionThe COVID-19 pandemic has an excessive impact on residents in long-term care facilities (LTCF), causing high morbidity and mortality. Early detection of presymptomatic and asymptomatic COVID-19 cases supports the timely implementation of effective outbreak control measures but repetitive screening of residents and staff incurs costs and discomfort. Administration of vaccines is key to controlling the pandemic but the robustness and longevity of the antibody response, correlation of neutralising antibodies with commercial antibody assays, and the efficacy of current vaccines for emerging COVID-19 variants require further study. We propose to monitor SARS-CoV-2 in site-specific sewage as an early warning system for COVID-19 in LTCF and to study the immune response of the staff and residents in LTCF to COVID-19 vaccines.Methods and analysisThe study includes two parts: (1) detection and quantification of SARS-CoV-2 in LTCF site-specific sewage samples using a molecular assay followed by notification of Public Health within 24 hours as an early warning system for appropriate outbreak investigation and control measures and cost–benefit analyses of the system and (2) testing for SARS-CoV-2 antibodies among staff and residents in LTCF at various time points before and after COVID-19 vaccination using commercial assays and neutralising antibody testing performed at a reference laboratory.Ethics and disseminationEthics approval was obtained from the University of Alberta Health Research Ethics Board with considerations to minimise risk and discomforts for the participants. Early recognition of a COVID-19 case in an LTCF might prevent further transmission in residents and staff. There was no direct benefit identified to the participants of the immunity study. Anticipated dissemination of information includes a summary report to the immunity study participants, sharing of study data with the scientific community through the Canadian COVID-19 Immunity Task Force, and prompt dissemination of study results in meeting s and manuscripts in peer-reviewed journals.

9.
J Environ Sci (China) ; 125: 843-850, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-1819537

ABSTRACT

With a unique and large size of testing results of 1,842 samples collected from 12 wastewater treatment plants (WWTP) for 14 months through from low to high prevalence of COVID-19, the sensitivity of RT-qPCR detection of SARS-CoV-2 RNA in wastewater that correspond to the communities was computed by using Probit analysis. This study determined the number of new COVID-19 cases per 100,000 population required to detect SARS-CoV-2 RNA in wastewater at defined probabilities and provided an evidence-based framework of wastewater-based epidemiology surveillance (WBE). Input data were positive and negative test results of SARS-CoV-2 RNA in wastewater samples and the corresponding new COVID-19 case rates per 100,000 population served by each WWTP. The analyses determined that RT-qPCR-based SARS-CoV-2 RNA detection threshold at 50%, 80% and 99% probability required a median of 8 (range: 4-19), 18 (9-43), and 38 (17-97) of new COVID-19 cases /100,000, respectively. Namely, the positive detection rate at 50%, 80% and 99% probability were 0.01%, 0.02%, and 0.04% averagely for new cases in the population. This study improves understanding of the performance of WBE SARS-CoV-2 RNA detection using the large datasets and prolonged study period. Estimated COVID-19 burden at a community level that would result in a positive detection of SARS-CoV-2 in wastewater is critical to support WBE application as a supplementary warning/monitoring system for COVID-19 prevention and control.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , SARS-CoV-2/genetics , Wastewater/analysis , RNA, Viral/genetics , RNA, Viral/analysis , Alberta/epidemiology
11.
J Water Health ; 20(1): 246-270, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1594180

ABSTRACT

The severe health consequences and global spread of the COVID-19 pandemic have necessitated the rapid development of surveillance programs to inform public health responses. Efforts to support surveillance capacity have included an unprecedented global research response into the use of genetic signals of SARS-CoV-2 in wastewater following the initial demonstration of the virus' detectability in wastewater in early 2020. The confirmation of fecal shedding of SARS-CoV-2 from asymptomatic, infected and recovering individuals further supports the potential for wastewater analysis to augment public health conventional surveillance techniques based on clinical testing of symptomatic individuals. We have reviewed possible capabilities projected for wastewater surveillance to support pandemic management, including independent, objective and cost-effective data generation that complements and addresses attendant limitations of clinical surveillance, early detection (i.e., prior to clinical reporting) of infection, estimation of disease prevalence, tracking of trends as possible indicators of success or failure of public health measures (mask mandates, lockdowns, vaccination, etc.), informing and engaging the public about pandemic trends, an application within sewer networks to identify infection hotspots, monitoring for presence or changes in infections from institutions (e.g., long-term care facilities, prisons, educational institutions and vulnerable industrial plants) and tracking of appearance/progression of viral variants of concern.


Subject(s)
COVID-19 , Wastewater , Communicable Disease Control , Humans , Pandemics , Public Health , SARS-CoV-2 , Wastewater-Based Epidemiological Monitoring
12.
Sci Total Environ ; 812: 151434, 2022 Mar 15.
Article in English | MEDLINE | ID: covidwho-1500243

ABSTRACT

Wastewater surveillance of SARS-CoV-2 has become a promising tool to estimate population-level changes in community infections and the prevalence of COVID-19 disease. Although many studies have reported the detection and quantification of SARS-CoV-2 in wastewater, remarkable variation remains in the methodology. In this study, we validated a molecular testing method by concentrating viruses from wastewater using ultrafiltration and detecting SARS-CoV-2 using one-step RT-qPCR assay. The following parameters were optimized including sample storage condition, wastewater pH, RNA extraction and RT-qPCR assay by quantification of SARS-CoV-2 or spiked human coronavirus strain 229E (hCoV-229E). Wastewater samples stored at 4 °C after collection showed significantly enhanced detection of SARS-CoV-2 with approximately 2-3 PCR-cycle threshold (Ct) values less when compared to samples stored at -20 °C. Pre-adjustment of the wastewater pH to 9.6 to aid virus desorption followed by pH readjustment to neutral after solid removal significantly increased the recovery of spiked hCoV-229E. Of the five commercially available RNA isolation kits evaluated, the MagMAX-96 viral RNA isolation kit showed the best recovery of hCoV-229E (50.1 ± 20.1%). Compared with two-step RT-qPCR, one-step RT-qPCR improved sensitivity for SARS-CoV-2 detection. Salmon DNA was included for monitoring PCR inhibition and pepper mild mottle virus (PMMoV), a fecal indicator indigenous to wastewater, was used to normalize SARS-CoV-2 levels in wastewater. Our method for molecular detection of SARS-CoV-2 in wastewater provides a useful tool for public health surveillance of COVID-19.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , RNA, Viral , Wastewater , Wastewater-Based Epidemiological Monitoring
13.
Environ Sci Technol ; 55(13): 8484-8491, 2021 07 06.
Article in English | MEDLINE | ID: covidwho-1260915

ABSTRACT

The COVID-19 pandemic has given rise to rapid and widespread international pursuit of wastewater surveillance for genetic signals of SARS-CoV-2, the virus causing the pandemic. Environmental scientists and engineers familiar with the techniques required for this endeavor have responded. Many of the environmental scientists engaged in these investigations have not necessarily had experience with the ethical obligations associated with generating and handling human health data. The Canadian Water Network facilitated adoption of these surveillance methods by creating a national coalition, which included a public health advisory group that recognized a need for ethics guidance for the wastewater approach to public health surveillance. This Policy Analysis addresses that need and is based on a review of relevant ethics literature tightly focused on ethics applicable to public health surveillance. That review revealed that classical health bioethics governing clinical practice and general public health ethics guidance did not adequately address key issues in wastewater surveillance. The 2017 World Health Organization guidelines, directly based on a systematic literature review, specifically addressed ethical issues in public health surveillance. The application of relevant ethical guidance to wastewater surveillance is analyzed and summarized for environmental scientists.


Subject(s)
COVID-19 , Pandemics , Canada , Humans , SARS-CoV-2 , Wastewater
14.
J Environ Sci (China) ; 107: 218-229, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1116983

ABSTRACT

Detection of SARS-CoV-2 RNA in wastewater is a promising tool for informing public health decisions during the COVID-19 pandemic. However, approaches for its analysis by use of reverse transcription quantitative polymerase chain reaction (RT-qPCR) are still far from standardized globally. To characterize inter- and intra-laboratory variability among results when using various methods deployed across Canada, aliquots from a real wastewater sample were spiked with surrogates of SARS-CoV-2 (gamma-radiation inactivated SARS-CoV-2 and human coronavirus strain 229E [HCoV-229E]) at low and high levels then provided "blind" to eight laboratories. Concentration estimates reported by individual laboratories were consistently within a 1.0-log10 range for aliquots of the same spiked condition. All laboratories distinguished between low- and high-spikes for both surrogates. As expected, greater variability was observed in the results amongst laboratories than within individual laboratories, but SARS-CoV-2 RNA concentration estimates for each spiked condition remained mostly within 1.0-log10 ranges. The no-spike wastewater aliquots provided yielded non-detects or trace levels (<20 gene copies/mL) of SARS-CoV-2 RNA. Detections appear linked to methods that included or focused on the solids fraction of the wastewater matrix and might represent in-situ SARS-CoV-2 to the wastewater sample. HCoV-229E RNA was not detected in the no-spike aliquots. Overall, all methods yielded comparable results at the conditions tested. Partitioning behavior of SARS-CoV-2 and spiked surrogates in wastewater should be considered to evaluate method effectiveness. A consistent method and laboratory to explore wastewater SARS-CoV-2 temporal trends for a given system, with appropriate quality control protocols and documented in adequate detail should succeed.


Subject(s)
COVID-19 , RNA, Viral , Humans , Laboratories , Pandemics , SARS-CoV-2 , Wastewater
SELECTION OF CITATIONS
SEARCH DETAIL